{"product_id":"dyness-stack-314-hv-batterijmodule-16-076-kwh","title":"Dyness Stack 314 HV Battery module 16.076 kWh","description":"\u003cdiv class=\"product-section\"\u003e\n\n  \u003cp class=\"p4\"\u003eThe \u003cstrong\u003eDyness Stack 314 HV Battery Module\u003c\/strong\u003e (model S51314) is a high-voltage LiFePO₄ battery module with a nominal capacity of \u003cstrong\u003e16.076 kWh\u003c\/strong\u003e (15.272 kWh usable) per module. The module operates at a nominal voltage of \u003cstrong\u003e51.2 V\u003c\/strong\u003e and is part of the modular STACK314 system. By connecting 3 to 15 modules in series, a system voltage of \u003cstrong\u003e134.4 to 864 V\u003c\/strong\u003e is achieved. Up to 12 clusters can be connected in parallel for a maximum system capacity of \u003cstrong\u003e2.89 MWh\u003c\/strong\u003e. The module requires a separate \u003cstrong\u003e\u003ca href=\"https:\/\/www.shop-rebor.com\/en\/products\/dyness-stack-314-bdu-base-besturingseenheid\" title=\"Dyness Stack 314 BDU \u0026amp; Base control unit\"\u003eDyness Stack 314 BDU \u0026amp; Base\u003c\/a\u003e\u003c\/strong\u003e control unit for operation. Modules from different production dates may be mixed within three years — flexible for future expansion.\u003c\/p\u003e\n\n  \u003cul class=\"usp-list\"\u003e\n    \u003cli\u003e\u003cstrong\u003eHigh energy density:\u003c\/strong\u003e 16.076 kWh nominal (15.272 kWh usable) per module at 314 Ah and 51.2 V nominal.\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eMaximum scalability:\u003c\/strong\u003e 3–15 modules in series (134.4–864 V), up to 12 clusters in parallel — maximum 2.89 MWh.\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eCable-free installation:\u003c\/strong\u003e plug-and-play stacking connection between modules — no separate DC cables between modules required.\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eLong service life:\u003c\/strong\u003e ≥8,000 charge\/discharge cycles and 10-year manufacturer warranty.\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eSafe LiFePO₄ chemistry:\u003c\/strong\u003e thermally stable, integrated aerosol fire extinguisher detects and extinguishes fires within 5 seconds.\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eModule mixing:\u003c\/strong\u003e modules from different production dates may be mixed within three years.\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eCertified:\u003c\/strong\u003e UN38.3, CE-EMC and IEC62619 certified for professional installation and operation.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003eTechnical notes for installers\u003c\/h2\u003e\n\n  \u003cp class=\"p4\"\u003eThe Stack 314 HV Battery Module is suitable for indoor use only (\u003cstrong\u003eIP20\u003c\/strong\u003e). Each module weighs \u003cstrong\u003e115 kg\u003c\/strong\u003e and has dimensions of \u003cstrong\u003e770 × 425 × 230 mm\u003c\/strong\u003e; installation requires a minimum of two persons. For more than 5 modules in series, the use of a hoist or lifting equipment is recommended. Cluster height is 293 + 230 × n mm (where n is the number of modules, maximum 8 per column). If more than 8 modules are required, two columns must be used. For installations on an upper floor, the load-bearing capacity must be assessed by a structural professional — cluster weight is 38 + 115 × n kg. The recommended charge\/discharge current is \u003cstrong\u003e140 A\u003c\/strong\u003e (0.45C); the maximum continuous current is \u003cstrong\u003e200 A\u003c\/strong\u003e (0.64C) and the peak current is \u003cstrong\u003e280 A\u003c\/strong\u003e for 2 minutes at 25 °C.\u003c\/p\u003e\n\n  \u003cdiv class=\"alert-box\"\u003e\n    \u003cstrong\u003ePlease note:\u003c\/strong\u003e This product is a single battery module. The \u003cstrong\u003e\u003ca href=\"https:\/\/www.shop-rebor.com\/en\/products\/dyness-stack-314-bdu-base-besturingseenheid\" title=\"Dyness Stack 314 BDU \u0026amp; Base control unit\"\u003eDyness Stack 314 BDU \u0026amp; Base\u003c\/a\u003e\u003c\/strong\u003e (control unit) is sold separately and is required for the operation of this system. A minimum of 3 modules is required for a functional system. Installation by certified electricians only, in accordance with applicable national standards.\n  \u003c\/div\u003e\n\n  \u003ctable\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003cth\u003eParameter\u003c\/th\u003e\n        \u003cth\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eChemistry\u003c\/td\u003e\n        \u003ctd\u003eLiFePO₄ (LFP)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eModel number\u003c\/td\u003e\n        \u003ctd\u003eS51314\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eNominal voltage per module\u003c\/td\u003e\n        \u003ctd\u003e51.2 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eCapacity per module\u003c\/td\u003e\n        \u003ctd\u003e314 Ah\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eNominal energy per module\u003c\/td\u003e\n        \u003ctd\u003e16.076 kWh\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eUsable energy per module\u003c\/td\u003e\n        \u003ctd\u003e15.272 kWh (95% DoD)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eDepth of discharge (DoD)\u003c\/td\u003e\n        \u003ctd\u003e95%\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eOperating voltage (3–15S)\u003c\/td\u003e\n        \u003ctd\u003e134.4–864 V\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eSystem capacity (1 cluster)\u003c\/td\u003e\n        \u003ctd\u003e48.228–241.14 kWh\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eMax. system capacity (12 clusters parallel)\u003c\/td\u003e\n        \u003ctd\u003e2.89 MWh\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eRecommended charge\/discharge current\u003c\/td\u003e\n        \u003ctd\u003e140 A (0.45C)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eMax. continuous charge\/discharge current\u003c\/td\u003e\n        \u003ctd\u003e200 A (0.64C)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003ePeak discharge current (25 °C)\u003c\/td\u003e\n        \u003ctd\u003e280 A, 2 min\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eRecommended charge\/discharge power\u003c\/td\u003e\n        \u003ctd\u003e7.168 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eMax. charge\/discharge power\u003c\/td\u003e\n        \u003ctd\u003e10.24 kW\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eCycle life\u003c\/td\u003e\n        \u003ctd\u003e≥8,000 cycles (0.2C, 25 °C, 95% DoD, 70% EOL)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eWarranty\u003c\/td\u003e\n        \u003ctd\u003e10 years\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eMin. modules per cluster\u003c\/td\u003e\n        \u003ctd\u003e3\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eMax. modules in series\u003c\/td\u003e\n        \u003ctd\u003e15\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eMax. modules per column (recommended)\u003c\/td\u003e\n        \u003ctd\u003e8\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eMax. clusters in parallel\u003c\/td\u003e\n        \u003ctd\u003e12\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eModule dimensions (W × D × H)\u003c\/td\u003e\n        \u003ctd\u003e770 × 425 × 230 mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eWeight per module\u003c\/td\u003e\n        \u003ctd\u003e115 kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eCluster height (n modules)\u003c\/td\u003e\n        \u003ctd\u003e293 + 230 × n mm\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eCluster weight (n modules)\u003c\/td\u003e\n        \u003ctd\u003e38 + 115 × n kg\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eProtection rating\u003c\/td\u003e\n        \u003ctd\u003eIP20 (indoor use only)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eCooling\u003c\/td\u003e\n        \u003ctd\u003eForced air cooling\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eCharging temperature\u003c\/td\u003e\n        \u003ctd\u003e0 °C to +55 °C (optional: −20 °C to +55 °C)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eDischarging temperature\u003c\/td\u003e\n        \u003ctd\u003e−20 °C to +55 °C\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eCommunication (via BDU)\u003c\/td\u003e\n        \u003ctd\u003eCAN \/ RS485\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eUser interface\u003c\/td\u003e\n        \u003ctd\u003eWiFi + App\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eInstallation method\u003c\/td\u003e\n        \u003ctd\u003eCable-free stacking (plug-and-play)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eFire protection\u003c\/td\u003e\n        \u003ctd\u003eIntegrated aerosol fire extinguisher (\u0026lt;5 seconds)\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003ctd\u003eCertifications\u003c\/td\u003e\n        \u003ctd\u003eUN38.3 · CE-EMC · IEC62619\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv class=\"cta-group\"\u003e\n    \u003ca class=\"cta-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0882\/5641\/4023\/files\/Datasheet_Dyness_STACK314_20260331.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload Datasheet\u003c\/a\u003e\n    \u003ca class=\"cta-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0882\/5641\/4023\/files\/Manual_STACK314-EN-V1.0-20260707.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload Installation Manual\u003c\/a\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"accordion\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\n\n    \u003cdetails itemscope=\"\" itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003csummary itemprop=\"name\"\u003eWhat is included in the Dyness Stack 314 HV Battery Module package?\u003c\/summary\u003e\n      \u003cdiv class=\"accordion-content\" itemscope=\"\" itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cdiv itemprop=\"text\"\u003e\n          \u003cp\u003eThe package contains the following components:\u003c\/p\u003e\n          \u003ctable\u003e\n            \u003ctbody\u003e\n              \u003ctr\u003e\n                \u003cth\u003eItem\u003c\/th\u003e\n                \u003cth\u003eQuantity\u003c\/th\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eS51314 Battery module\u003c\/td\u003e\n                \u003ctd\u003e1\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003eFlat head screws M5×30\u003c\/td\u003e\n                \u003ctd\u003e4\u003c\/td\u003e\n              \u003c\/tr\u003e\n              \u003ctr\u003e\n                \u003ctd\u003ePacking list\u003c\/td\u003e\n                \u003ctd\u003e1\u003c\/td\u003e\n              \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n          \u003c\/table\u003e\n          \u003cp\u003eThe \u003ca href=\"https:\/\/www.shop-rebor.com\/en\/products\/dyness-stack-314-bdu-base-besturingseenheid\" title=\"Dyness Stack 314 BDU \u0026amp; Base control unit\"\u003eDyness Stack 314 BDU \u0026amp; Base\u003c\/a\u003e (control unit) is not included and is sold separately. A minimum of 3 modules is required for a functional system.\u003c\/p\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails itemscope=\"\" itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003csummary itemprop=\"name\"\u003eWhich inverters are compatible with the Dyness Stack 314?\u003c\/summary\u003e\n      \u003cdiv class=\"accordion-content\" itemscope=\"\" itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cdiv itemprop=\"text\"\u003e\n          \u003cp\u003eThe STACK314 system communicates via CAN or RS485 (via the BDU) and is compatible with, among others: \u003cstrong\u003eATESS, Deye, Growatt, Megarevo, Solinteg, Solis, Sosen and Sinexcel\u003c\/strong\u003e. Please consult the installation manual and the current Dyness compatibility list for model-specific and settings details per inverter type.\u003c\/p\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails itemscope=\"\" itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003csummary itemprop=\"name\"\u003eHow many Stack 314 modules do I need for my system?\u003c\/summary\u003e\n      \u003cdiv class=\"accordion-content\" itemscope=\"\" itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cdiv itemprop=\"text\"\u003e\n          \u003cp\u003ePer cluster, \u003cstrong\u003e3 to 15 modules in series\u003c\/strong\u003e can be connected, resulting in a system capacity of 48.23 kWh to 241.14 kWh per cluster. A maximum of \u003cstrong\u003e8 modules per column\u003c\/strong\u003e is recommended (cluster height: 293 + 230 × n mm; cluster weight: 38 + 115 × n kg). If more than 8 modules are required, two columns must be used. Up to \u003cstrong\u003e12 clusters in parallel\u003c\/strong\u003e are possible for a maximum system capacity of \u003cstrong\u003e2.89 MWh\u003c\/strong\u003e. Modules from different production dates may be mixed within three years.\u003c\/p\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails itemscope=\"\" itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003csummary itemprop=\"name\"\u003eWhat are the installation requirements for the Dyness Stack 314 HV Battery Module?\u003c\/summary\u003e\n      \u003cdiv class=\"accordion-content\" itemscope=\"\" itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cdiv itemprop=\"text\"\u003e\n          \u003cp\u003eInstallation by certified electricians only, in accordance with applicable national standards. The system is suitable for indoor use only (IP20). Each module weighs 115 kg; installation requires a minimum of two persons. For more than 5 modules, a hoist is recommended. For installations on an upper floor, the load-bearing capacity must be assessed by a structural professional — cluster weight is 38 + 115 × n kg. If more than 8 modules are required, two columns must be used. Ensure adequate ventilation around the system for the forced air cooling. Please consult the \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0882\/5641\/4023\/files\/Manual_STACK314-EN-V1.0-20260707.pdf\" target=\"_blank\" rel=\"noopener\"\u003einstallation manual\u003c\/a\u003e for all installation requirements.\u003c\/p\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails itemscope=\"\" itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003csummary itemprop=\"name\"\u003eWhat is the difference between the Dyness Stack 314 and the Stack 280 battery module?\u003c\/summary\u003e\n      \u003cdiv class=\"accordion-content\" itemscope=\"\" itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cdiv itemprop=\"text\"\u003e\n          \u003cp\u003eThe Stack 314 module (S51314) has a nominal capacity of \u003cstrong\u003e16.076 kWh\u003c\/strong\u003e (314 Ah) compared to \u003cstrong\u003e14.34 kWh\u003c\/strong\u003e (280 Ah) for the Stack 280 module (S51280). The Stack 314 therefore offers higher energy density per module and a larger maximum system capacity of 2.89 MWh (vs. 2.58 MWh for the Stack 280). Both modules support cable-free stacking installation, forced air cooling, an integrated aerosol fire extinguisher and ≥8,000 cycles. The Stack 314 is specifically designed for small commercial and industrial applications where higher capacity per module is required.\u003c\/p\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n  \u003c\/div\u003e\n\n  \u003cp class=\"p4\"\u003eExplore more products in our \u003ca href=\"https:\/\/www.shop-rebor.com\/en\/collections\/byd-home-battery\" title=\"Home battery range Rebor\"\u003ehome battery range at Rebor\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003c\/div\u003e\n","brand":"Dyness","offers":[{"title":"Default Title","offer_id":54525862117703,"sku":"S51314","price":1620.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0882\/5641\/4023\/files\/Dyness_Stack314_Battery_angled.png?v=1785932920","url":"https:\/\/www.shop-rebor.com\/en\/products\/dyness-stack-314-hv-batterijmodule-16-076-kwh","provider":"Rebor B.V.","version":"1.0","type":"link"}