{"product_id":"solis-epm3-5g-pro-export-power-manager","title":"Solis-EPM3-5G-PRO Export Power Manager","description":"\u003cdiv class=\"product-section\"\u003e\n\n  \u003cp class=\"p4\"\u003e\n    The \u003cstrong\u003eSolis-EPM3-5G-PRO\u003c\/strong\u003e is a professional \u003cstrong\u003eExport Power Manager\u003c\/strong\u003e designed for three-phase PV installations where controlled grid feed-in and regulatory compliance are mandatory. \n    The unit acts as a centralized measurement and control interface between Solis inverters, energy metering and the grid connection point.\n  \u003c\/p\u003e\n\n  \u003cp class=\"p4\"\u003e\n    Via \u003cstrong\u003eRS485 (Modbus RTU)\u003c\/strong\u003e, the EPM3-5G-PRO can simultaneously control up to \u003cstrong\u003e20 Solis inverters\u003c\/strong\u003e. \n    With a control accuracy of \u003cstrong\u003e±1%\u003c\/strong\u003e, total export power is dynamically limited based on real-time grid measurements.\n  \u003c\/p\u003e\n\n  \u003cul class=\"usp-list\"\u003e\n    \u003cli\u003e\u003cstrong\u003eExport Limitation:\u003c\/strong\u003e Configurable to 0W (zero-export) or a fixed export limit.\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eScalable Architecture:\u003c\/strong\u003e Centralized control of up to 20 inverters.\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eControl Accuracy ±1%:\u003c\/strong\u003e Stable and compliant grid integration.\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eRS485 (Modbus RTU):\u003c\/strong\u003e Industrial-grade wired communication interface.\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eFailsafe Mode:\u003c\/strong\u003e Configurable response in case of communication loss.\u003c\/li\u003e\n    \u003cli\u003e\u003cstrong\u003eIP65 Enclosure:\u003c\/strong\u003e Suitable for indoor and protected outdoor installation.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003eGrid-Compliant Power Management\u003c\/h2\u003e\n\n  \u003cp class=\"p4\"\u003e\n    The EPM3-5G-PRO continuously measures import and export power through an external energy meter and dynamically adjusts connected inverters to ensure that the defined export limit is not exceeded. \n    This supports compliance with grid operator requirements, contractual feed-in limitations and regional regulatory frameworks.\n  \u003c\/p\u003e\n\n  \u003cdiv class=\"alert-box\"\u003e\n    \u003cstrong\u003eInstallation Note:\u003c\/strong\u003e When applying external EPM control, the internal export limitation function within the inverter must be disabled. \n    The correct failsafe configuration according to the official manual is required to prevent control conflicts.\n  \u003c\/div\u003e\n\n  \u003ch2\u003eCore Specifications\u003c\/h2\u003e\n\n  \u003ctable\u003e\n    \u003ctbody\u003e\n\n      \u003ctr\u003e\n        \u003cth\u003eProperty\u003c\/th\u003e\n        \u003cth\u003eValue\u003c\/th\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eModel\u003c\/td\u003e\n        \u003ctd\u003eSolis-EPM3-5G-PRO\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eType\u003c\/td\u003e\n        \u003ctd\u003eThree-Phase Export Power Manager\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eMax. Inverters\u003c\/td\u003e\n        \u003ctd\u003e20 (via RS485)\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eCommunication\u003c\/td\u003e\n        \u003ctd\u003eRS485 (Modbus RTU)\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eControl Accuracy\u003c\/td\u003e\n        \u003ctd\u003e±1%\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eGrid Voltage\u003c\/td\u003e\n        \u003ctd\u003e1\/N\/PE 230V | 3\/N\/PE 400V | 3\/PE 480V\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eEnergy Meter\u003c\/td\u003e\n        \u003ctd\u003eAcrel ADL3000-E-B (3-phase, 5A secondary)\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eProtection Rating\u003c\/td\u003e\n        \u003ctd\u003eIP65\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n      \u003ctr\u003e\n        \u003ctd\u003eWarranty\u003c\/td\u003e\n        \u003ctd\u003e2 Years\u003c\/td\u003e\n      \u003c\/tr\u003e\n\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv class=\"accordion\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\n\n    \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003csummary itemprop=\"name\"\u003eWhat does an Export Power Manager do?\u003c\/summary\u003e\n      \u003cdiv class=\"accordion-content\" itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cdiv itemprop=\"text\"\u003e\n          \u003cp\u003e\n            An Export Power Manager continuously measures grid power flow and adjusts connected inverters so that a defined export limit \n            (for example 0W or a fixed maximum value) is not exceeded.\n          \u003c\/p\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003csummary itemprop=\"name\"\u003eHow many inverters can be connected?\u003c\/summary\u003e\n      \u003cdiv class=\"accordion-content\" itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cdiv itemprop=\"text\"\u003e\n          \u003cp\u003e\n            The EPM3-5G-PRO supports up to 20 Solis inverters via the RS485 communication interface.\n          \u003c\/p\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003csummary itemprop=\"name\"\u003eWhat is included in the delivery?\u003c\/summary\u003e\n      \u003cdiv class=\"accordion-content\" itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cdiv itemprop=\"text\"\u003e\n          \u003cul\u003e\n            \u003cli\u003eEPM3-5G-PRO unit\u003c\/li\u003e\n            \u003cli\u003eBack Plate\u003c\/li\u003e\n            \u003cli\u003eNecessary screws\u003c\/li\u003e\n            \u003cli\u003eAC Connector\u003c\/li\u003e\n            \u003cli\u003eAcrel ADL energy meter without CTs (5A secondary current required)\u003c\/li\u003e\n            \u003cli\u003e5× RS485 communication terminals\u003c\/li\u003e\n            \u003cli\u003eRJ45 connector\u003c\/li\u003e\n            \u003cli\u003eUser manual \u0026 Quick Installation Guide\u003c\/li\u003e\n          \u003c\/ul\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003csummary itemprop=\"name\"\u003eAre current transformers (CTs) included?\u003c\/summary\u003e\n      \u003cdiv class=\"accordion-content\" itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cdiv itemprop=\"text\"\u003e\n          \u003cp\u003e\n            The energy meter used is an \u003cstrong\u003eAcrel ADL3000-E-B\u003c\/strong\u003e with a 5A secondary input. \n            External current transformers (CTs) are required and are typically not included in the standard package.\n          \u003c\/p\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n    \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n      \u003csummary itemprop=\"name\"\u003eIs zero-export (0W) configuration possible?\u003c\/summary\u003e\n      \u003cdiv class=\"accordion-content\" itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n        \u003cdiv itemprop=\"text\"\u003e\n          \u003cp\u003e\n            Yes. The export limit can be configured for full zero-export operation or for a defined maximum feed-in value.\n          \u003c\/p\u003e\n        \u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/details\u003e\n\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"cta-group\"\u003e\n    \u003ca class=\"cta-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0882\/5641\/4023\/files\/Datasheet_Solis-EPM-5G.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e\n    \u003ca class=\"cta-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0882\/5641\/4023\/files\/Manual_EPM-5G.pdf\" target=\"_blank\"\u003eDownload Manual\u003c\/a\u003e\n  \u003c\/div\u003e\n\n  \u003cp class=\"p4\"\u003e\n    Discover more products in our \n    \u003ca href=\"https:\/\/www.shop-rebor.com\/en\/collections\/solis-inverters\" title=\"Solis Inverters\"\u003eSolis Inverters\u003c\/a\u003e collection.\n  \u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Ginlong (Solis) Technologies","offers":[{"title":"Default Title","offer_id":53423350350151,"sku":"Solis-EPM3-5G-PRO","price":330.54,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0882\/5641\/4023\/files\/Solis-EPM-Export-manager-5G-pro.webp?v=1772227640","url":"https:\/\/www.shop-rebor.com\/en\/products\/solis-epm3-5g-pro-export-power-manager","provider":"Rebor B.V.","version":"1.0","type":"link"}