{"product_id":"solis-s6-eh3p100k10-nv-yd-h-100-kw-3-fasen-hybride-omvormer","title":"Solis S6-EH3P100K10-NV-YD-H 100 kW 3-phase Hybrid Inverter","description":"\u003cdiv class=\"product-section\"\u003e\n\u003cp class=\"p4\"\u003eThe \u003cstrong\u003eSolis S6-EH3P100K10-NV-YD-H\u003c\/strong\u003e is a powerful three-phase hybrid inverter for commercial and industrial energy systems with high-voltage batteries. With a rated output power of \u003cstrong\u003e100 kW\u003c\/strong\u003e and a maximum usable PV input power of \u003cstrong\u003e200 kW\u003c\/strong\u003e, this system provides maximum self-sufficiency capacity on a large scale. The inverter offers reliable backup functionality with a switching time of \u003cstrong\u003e\u0026lt;10ms\u003c\/strong\u003e and can be scaled up to \u003cstrong\u003e1.25 MW\u003c\/strong\u003e through parallel operation. Designed for professional installations with the highest demands for power, stability and flexibility.\u003c\/p\u003e\n\n\u003cul class=\"usp-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePV capacity:\u003c\/strong\u003e Supports \u003cstrong\u003e200 kW\u003c\/strong\u003e maximum usable PV input power (recommended array size: 200 kW) via \u003cstrong\u003e10 MPPT inputs\u003c\/strong\u003e and up to 20 strings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharge\/discharge current:\u003c\/strong\u003e Maximum charge\/discharge current of \u003cstrong\u003e200 A\u003c\/strong\u003e (100 A per port × 2 independent battery ports) for fast energy storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching time:\u003c\/strong\u003e Backup power is activated in \u003cstrong\u003e\u0026lt;10ms\u003c\/strong\u003e during a grid outage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload capability:\u003c\/strong\u003e \u003cstrong\u003e160%\u003c\/strong\u003e overload for 10 seconds and \u003cstrong\u003e200%\u003c\/strong\u003e for 200ms in off-grid mode for starting heavy loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalability:\u003c\/strong\u003e Parallel operation up to \u003cstrong\u003e1.25 MW\u003c\/strong\u003e (Solis STS cabinet recommended when using more than 6 units).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery compatibility:\u003c\/strong\u003e Compatible with \u003cstrong\u003e100–314 Ah\u003c\/strong\u003e Li-ion battery modules within a \u003cstrong\u003e300–950 V\u003c\/strong\u003e high-voltage range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e100 kW Commercial Hybrid Power with \u0026lt;10ms Backup – Solis S6\u003c\/h2\u003e\n\n\u003cp class=\"p4\"\u003eThe Solis S6-EH3P100K10-NV-YD-H provides a robust solution for large-scale energy systems. With \u003cstrong\u003e10 MPPT inputs\u003c\/strong\u003e and up to \u003cstrong\u003e20 PV strings\u003c\/strong\u003e, a maximum input current of \u003cstrong\u003e10 × 42 A\u003c\/strong\u003e and a maximum current per DC input of \u003cstrong\u003e42 A\u003c\/strong\u003e, the inverter is compatible with high-power solar modules — including modules from \u003ca href=\"\/en\/collections\/aiko-module\"\u003eAiko\u003c\/a\u003e and \u003ca href=\"\/en\/collections\/trina-module\"\u003eTrina Solar\u003c\/a\u003e. The backup port provides a rated output power of \u003cstrong\u003e100 kW\u003c\/strong\u003e and supports peaks of up to \u003cstrong\u003e1.6× rated power for 10 seconds\u003c\/strong\u003e. Per phase, the inverter provides up to \u003cstrong\u003e33% of rated power\u003c\/strong\u003e. The system features two independent battery ports for flexible configurations and easy capacity expansion. With \u003cstrong\u003eIP66\u003c\/strong\u003e protection, an operating temperature range of \u003cstrong\u003e-25°C to +60°C\u003c\/strong\u003e and patented \u003cstrong\u003eIntelligent Redundant Fan Cooling\u003c\/strong\u003e, this system is designed for demanding operating conditions.\u003c\/p\u003e\n\n\u003cdiv class=\"alert-box\"\u003ePlease note: The inverter weighs \u003cstrong\u003e170 kg\u003c\/strong\u003e — only use professional lifting equipment with sufficient load capacity during installation. The battery fuse may only be replaced by Solis-authorised personnel. Use approved 4.0–6.0 mm² DC cables (PV) and recommended 25–35 mm² battery cables for installation. Minimum clearance: \u003cstrong\u003e200 mm\u003c\/strong\u003e above, \u003cstrong\u003e450 mm\u003c\/strong\u003e left\/right, \u003cstrong\u003e400 mm\u003c\/strong\u003e below and \u003cstrong\u003e1000 mm\u003c\/strong\u003e in front.\u003c\/div\u003e\n\n\u003ch2\u003eComplete Technical Specifications – Solis 100kW Hybrid Inverter\u003c\/h2\u003e\n\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand \u0026amp; Model\u003c\/td\u003e\n\u003ctd\u003eSolis S6-EH3P100K10-NV-YD-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power\u003c\/td\u003e\n\u003ctd\u003e100,000 W (100 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Usable PV Input Power\u003c\/td\u003e\n\u003ctd\u003e200 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Max. PV Array Size\u003c\/td\u003e\n\u003ctd\u003e200 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Input Voltage (PV)\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated PV Voltage\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart-up Voltage\u003c\/td\u003e\n\u003ctd\u003e180 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT Voltage Range\u003c\/td\u003e\n\u003ctd\u003e150–950 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Input Current (PV)\u003c\/td\u003e\n\u003ctd\u003e10 × 42 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Current per DC Input\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Short-Circuit Current\u003c\/td\u003e\n\u003ctd\u003e10 × 60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of MPPTs \/ Max. Strings\u003c\/td\u003e\n\u003ctd\u003e10 \/ 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eLi-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage Range\u003c\/td\u003e\n\u003ctd\u003e300–950 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Charge\/Discharge Current\u003c\/td\u003e\n\u003ctd\u003e100 A × 2 \/ 100 A × 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Ports \/ BMS Ports\u003c\/td\u003e\n\u003ctd\u003e2 \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Current per Battery Port\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Communication\u003c\/td\u003e\n\u003ctd\u003eCAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Grid Voltage\u003c\/td\u003e\n\u003ctd\u003e3\/N\/PE, 220V\/380V; 230V\/400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e151.9 A (380V) \/ 144.3 A (400V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power per Phase\u003c\/td\u003e\n\u003ctd\u003e33% of rated power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup Switching Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Backup Overload\u003c\/td\u003e\n\u003ctd\u003e1.6× rated power, 10 s \/ 2× rated power, 200 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC Pass-through Current\u003c\/td\u003e\n\u003ctd\u003e151.9 A (380V) \/ 144.3 A (400V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. AC Grid Input Current\u003c\/td\u003e\n\u003ctd\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Efficiency\u003c\/td\u003e\n\u003ctd\u003e97.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEU Efficiency\u003c\/td\u003e\n\u003ctd\u003e97.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Battery Charging Efficiency via PV\/AC\u003c\/td\u003e\n\u003ctd\u003e98.2% \/ 97.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Discharge Efficiency\u003c\/td\u003e\n\u003ctd\u003e97.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×H×D)\u003c\/td\u003e\n\u003ctd\u003e1174 × 814 × 400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e170 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Emission\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eIntelligent redundant fan-cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C ~ +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Operating Altitude\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eNon-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf-consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;45 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e7.0\" LCD \u0026amp; Bluetooth + APP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eWiFi + LAN + Bluetooth, CAN-BMS ×2, CAN-Parallel ×2, RS485-Meter, RS485, DRM, DI ×5, DO ×4; Optional: 4G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 62109-1\/-2, IEC\/EN 61000-6-2\/-4, EN 55011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eDC Type II \/ AC Type II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 years (extendable up to 20 years)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cdiv class=\"cta-group\"\u003e\n\u003ca class=\"cta-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0882\/5641\/4023\/files\/Datasheet_S6-EH3P_75-125_K10-NV-YD-H.pdf\" target=\"_blank\"\u003eDownload Datasheet\u003c\/a\u003e \u003ca class=\"cta-btn\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0882\/5641\/4023\/files\/Manual_S6-EH3P_75-125_K10-NV-YD-H.pdf\" target=\"_blank\"\u003eView Manual\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"accordion\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\n\n\u003cdetails itemscope=\"\" itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003csummary itemprop=\"name\"\u003eWhat is included with the Solis S6-EH3P100K10-NV-YD-H?\u003c\/summary\u003e\n\u003cdiv class=\"accordion-content\" itemscope=\"\" itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp class=\"p4\"\u003eThe package includes: Inverter ×1, Back plate ×1, Hex Head Bolt Assembly M10×40 ×4, Flat Washer Ø10 ×4, Hex Nut M10 ×4, Phillips Hex Head Bolt M10×20 ×8, Expansion Bolt M10×70 ×4, Phillips Hex Head Combination Screw M8×20 ×2, RJ45 connector ×10, DC connector ×20, Through-wall terminal wiring cover ×5, Through-wall Terminal Cover (Black) ×2, Through-wall Terminal Cover (Orange) ×2, Handle ×4, CT ×3, CT cables ×1, Dual RJ45 Plug Shielded Cable Harness 5000mm ×1, Eastron Meter (optional) ×1, Lifting Buckle ×2, L-type spanner ×1, S2-WL-ST Data logger ×1 and Quick Installation Manual ×1. Check upon receipt that all components are present. If any items are missing, contact your Solis distributor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails itemscope=\"\" itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003csummary itemprop=\"name\"\u003eWhich batteries are compatible with the Solis S6-EH3P100K10-NV-YD-H?\u003c\/summary\u003e\n\u003cdiv class=\"accordion-content\" itemscope=\"\" itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp class=\"p4\"\u003eThe inverter is compatible exclusively with \u003cstrong\u003eLi-ion high-voltage batteries\u003c\/strong\u003e within a voltage range of \u003cstrong\u003e300–950 V\u003c\/strong\u003e and a capacity of \u003cstrong\u003e100–314 Ah\u003c\/strong\u003e. The inverter features \u003cstrong\u003e2 independent battery ports\u003c\/strong\u003e (max. 100 A each) for flexible configurations: 1 battery connected to 1 DC port, 1 battery connected to 2 DC ports, or 2 separate batteries. Compatible battery brands (according to the official Solis Battery Matching List) include \u003cstrong\u003ePylontech\u003c\/strong\u003e and \u003cstrong\u003eDyness\u003c\/strong\u003e. Always consult the latest compatibility list on the \u003ca href=\"\/en\/collections\/solis-inverters\"\u003eSolis product page\u003c\/a\u003e for the most recently approved batteries.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails itemscope=\"\" itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003csummary itemprop=\"name\"\u003eWhat should I consider when installing this 100kW inverter?\u003c\/summary\u003e\n\u003cdiv class=\"accordion-content\" itemscope=\"\" itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp class=\"p4\"\u003eThe Solis S6-EH3P100K10-NV-YD-H weighs \u003cstrong\u003e170 kg\u003c\/strong\u003e and requires professional lifting equipment with sufficient load capacity. Mount the inverter vertically on a non-combustible surface with a load-bearing capacity of at least 4× the weight of the unit. Maintain at least \u003cstrong\u003e200 mm\u003c\/strong\u003e clearance above, \u003cstrong\u003e450 mm\u003c\/strong\u003e on the left and right, \u003cstrong\u003e400 mm\u003c\/strong\u003e below and \u003cstrong\u003e1000 mm\u003c\/strong\u003e in front of the inverter. For multiple inverters, maintain at least \u003cstrong\u003e800 mm\u003c\/strong\u003e spacing. Installation must only be carried out by a qualified electrician. Use recommended \u003cstrong\u003e25–35 mm²\u003c\/strong\u003e battery cables, \u003cstrong\u003e70 mm²\u003c\/strong\u003e backup cables and \u003cstrong\u003e95 mm²\u003c\/strong\u003e grid cables. The system has an \u003cstrong\u003eIP66\u003c\/strong\u003e protection rating and is suitable for indoor and outdoor installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails itemscope=\"\" itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003csummary itemprop=\"name\"\u003eIs this inverter Battery-Ready and does it work with SolisCloud?\u003c\/summary\u003e\n\u003cdiv class=\"accordion-content\" itemscope=\"\" itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp class=\"p4\"\u003eYes. The Solis S6-EH3P100K10-NV-YD-H is fully \u003cstrong\u003eBattery-Ready\u003c\/strong\u003e with two independent CAN-BMS ports for direct integration with approved high-voltage batteries. The integrated \u003cstrong\u003eWiFi + LAN + Bluetooth\u003c\/strong\u003e connectivity makes it easy to connect the inverter to the \u003cstrong\u003eSolisCloud\u003c\/strong\u003e platform for real-time monitoring, AI optimisation and remote troubleshooting. The inverter supports \u003cstrong\u003eTime-of-Use (TOU)\u003c\/strong\u003e settings, dynamic reactive power compensation, export limitation and AC coupling with existing PV installations — ideal for large-scale C\u0026amp;I projects seeking maximum energy independence.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003c\/div\u003e\n\n\u003cp class=\"p4\"\u003eExplore the complete range on our \u003ca href=\"\/en\/collections\/solis-inverters\"\u003e\u003cstrong\u003eSolis\u003c\/strong\u003e inverter page\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Ginlong (Solis) Technologies","offers":[{"title":"Default Title","offer_id":55359436816711,"sku":"S6-EH3P100K10-NV-YD-H","price":6795.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0882\/5641\/4023\/files\/Solis_S6-EH3P100K10-NV-YD-H_Fr.png?v=1791560010","url":"https:\/\/www.shop-rebor.com\/en\/products\/solis-s6-eh3p100k10-nv-yd-h-100-kw-3-fasen-hybride-omvormer","provider":"Rebor B.V.","version":"1.0","type":"link"}