End of the net-metering scheme in 2027: what does this mean for solar panels, self-consumption, and home batteries?
Key answer: the Dutch net-metering scheme (salderingsregeling) will end on January 1, 2027. Solar panels will continue to produce electricity and remain financially valuable, but the economic logic will change. The focus will no longer be on the annual offsetting of energy consumption and injection, but on the direct use of your own solar power, smart management of electrical appliances, and, where the energy profile justifies it, storing temporary PV surpluses in a home battery.
The most important design question for households with solar panels therefore becomes: how much of my solar power can I use directly, shift intelligently, or store in a technically sensible way before feeding it back into the power grid?
Last content review: September 2026.
As of January 1, 2027, the financial operation of solar panels in the Netherlands will fundamentally change. The net-metering scheme will end. From that moment on, injected solar power can no longer be offset against electricity drawn from the grid at a different time.
This does not mean that solar panels will lose their value. After all, every kilowatt-hour of solar power used directly in the home does not need to be purchased from an energy supplier.
The strategy therefore shifts from maximizing annual net-metering to creating as much value as possible behind your own meter.
This can be achieved by shifting consumption to sun-drenched hours, smart charging an electric vehicle, intelligently controlling a heat pump, and, when the technical and economic situation is suitable, properly sizing a home battery.
What exactly changes on January 1, 2027?
Up to and including December 31, 2026, households and small businesses covered by the scheme can offset injected electricity against electricity drawn from the grid, subject to legal conditions.
From January 1, 2027, this offsetting will cease.
Compensation for injected electricity will still exist. According to current information from the central government, the feed-in tariff must be at least 50% of the base supply rate until 2030. The base supply rate is the electricity tariff excluding taxes.
At the same time, energy suppliers can, under certain conditions, charge feed-in costs. The ultimate value of an injected kilowatt-hour is therefore determined by the energy contract, the base supply rate, the feed-in tariff, any applicable feed-in costs, and the contract terms.
Important distinction: the legal system and a calculation assumption are not the same. Milieu Centraal uses approximately 1.25 cents per injected kWh for fixed and variable contracts in its current sample calculations. This is a calculation starting point and not a guaranteed universal fee for every energy contract.
The new economic logic of solar panels from 2027
From 2027, the value of solar power can be roughly divided into two categories:
| Energy flow | Economic value | Why? |
|---|---|---|
| Directly self-consumed solar power | Relatively high | This electricity does not need to be purchased from the energy supplier. |
| Injected solar power | Contract-dependent and generally lower | The value is determined by the feed-in tariff, contract terms, and any applicable feed-in costs. |
This changes the most important KPI of a residential PV system.
Up to and including 2026, there was much emphasis on annual production in kWh. From 2027, the self-consumption rate will become much more important.
This rate describes what proportion of the generated solar power is used directly within the user's own installation.
What does the end of net-metering mean financially?
Milieu Centraal publishes current sample calculations to provide insight into the financial situation from 2027.
For an installation with 10 solar panels, Milieu Centraal currently calculates with a purchase price of approximately €3,800 and an annual energy bill saving from 2027 of approximately €260 per year, based on an average of 30% direct self-consumption.
The corresponding calculations for modern solar panels use approximately 435 Wp per panel. An installation of 10 panels thus results in approximately 4,350 Wp of installed PV capacity and approximately 3,800 kWh of annual production in the calculation example used.
| Example baseline | Value |
|---|---|
| Number of solar panels | 10 |
| Power per panel | Approx. 435 Wp |
| Total PV capacity | Approx. 4,350 Wp |
| Annual production in example | Approx. 3,800 kWh |
| Average direct self-consumption | Approx. 30% |
| Calculated annual savings from 2027 | Approx. €260 |
This €260 is explicitly not a guaranteed return for every installation. The actual financial outcome depends on, among other things, PV production, electricity consumption, usage profile, electricity price, feed-in tariff, feed-in costs, and the percentage of solar power used directly.
Why self-consumption becomes much more important from 2027
For an average household without active energy management, Milieu Centraal calculates with approximately 30% direct self-consumption. In such a scenario, about 70% of the solar power is not used in the home at the same time.
Under the net-metering scheme, the time difference between production and consumption could be largely offset financially through annual settlement.
From 2027, this mechanism will disappear.
Suppose solar panels produce 4 kW at 1:00 PM while the home only uses 1 kW. A surplus of approximately 3 kW is created at that moment.
When this power is injected, the owner receives the contractually applicable feed-in tariff. When the same home needs electricity at 7:00 PM while PV production is virtually zero, electricity must once again be drawn from the grid.
That is why a self-consumed kWh of solar power is economically different from an injected kWh.
Milieu Centraal summarizes this difference effectively: self-generated electricity that is used directly is approximately three to four times more economical in current calculations for a fixed or variable contract than electricity purchased from an energy supplier.
Increasing self-consumption does not automatically start with a home battery
Professional energy advice does not start immediately with storage.
The first step is to analyze which electrical loads can be shifted to sun-drenched hours. After all, direct use requires no battery conversion and requires no investment in storage capacity.
Examples include:
- running the washing machine and dishwasher during sun-drenched hours;
- scheduling the dryer smartly;
- charging an electric vehicle when sufficient PV power is available;
- operating a heat pump or storage tank during favorable solar moments, provided the installation technically supports this;
- using an energy management system to distribute available solar energy among various consumers.
Milieu Centraal shows that the average self-consumption for a household without large electrical consumers can rise from approximately 30% to 35% through more conscious use of the washing machine, dishwasher, and dryer.
For households with larger electrical consumers, higher percentages are mentioned in current examples. Smart use of a heat pump storage tank can move toward approximately 45% self-consumption, and charging an electric vehicle with your own solar power toward approximately 50%.
These are example situations. The actual percentage depends on PV capacity, consumption, presence times, weather conditions, control strategy, and the power of the connected equipment.
When does a home battery become relevant?
Not every household can shift sufficient electricity consumption to the middle of the day. A large part of residential consumption takes place in the morning, evening, and night.
In such a situation, a home battery can reduce the time difference between production and consumption.
The energy flow can then, for example, become:
Solar panels → direct home consumption → battery charging → later battery discharging to home consumption
Instead of:
Solar panels → injection to the grid → later repurchasing electricity
That makes battery storage more relevant from 2027 as an instrument for self-consumption optimization. But relevant does not automatically mean profitable.
A battery must technically and economically suit the actual energy profile.
Do not automatically view the loss of net-metering as battery yield
A common calculation error is to consider the entire financial difference between the current net-metering situation and the situation from 2027 as a potential return from a home battery.
That is technically incorrect.
A home battery can only create value with energy that:
- is actually available as a surplus;
- can be stored within the system's charging capacity;
- fits within the usable capacity of the battery;
- remains available after conversion losses;
- can actually be used later to avoid grid drawing;
- is economically more valuable at that later moment than direct injection.
Conceptually, the value of stored PV energy can be approximated with:
Economic storage value ≈ usable stored PV surplus × round-trip efficiency × avoided purchase value, corrected for the missed value of direct injection.
For a serious business case, battery degradation, available cycles, charging and discharging limits, system losses, investment, maintenance, any EMS costs, and future changes in the energy contract must also be included.
Why a battery should never be sized based on annual consumption alone
A commonly used rule of thumb like "10 kWh battery for a certain annual consumption" is insufficient for professional system design.
Two homes can both consume 4,000 kWh per year and still have completely different optimal battery capacities.
One home consumes electricity mainly in the evening and has a large daily PV surplus. The other home already uses a lot of the solar power directly during the day. In the second case, less energy is available to actually store in a battery.
Technically sound battery advice therefore assesses at least:
- annual electricity consumption;
- day and night consumption;
- quarter-hourly or hourly profile when available;
- annual PV production;
- daily PV surplus;
- seasonal differences;
- current direct self-consumption;
- desired self-consumption;
- nominal and usable battery capacity;
- permitted Depth of Discharge;
- maximum charging power;
- maximum discharging power;
- round-trip efficiency;
- maximum simultaneous home power;
- any backup load;
- future electric vehicle;
- future heat pump;
- energy contract and control strategy.
Self-consumption is not the same as self-sufficiency
For a professional analysis, it is important to distinguish between two concepts.
| KPI | Meaning |
|---|---|
| Self-consumption | The percentage of produced solar power that is used within your own installation. |
| Degree of self-sufficiency | The percentage of total electricity consumption that is covered by your own PV and, where applicable, battery storage. |
A high self-consumption rate therefore does not automatically mean that a home is largely independent of the power grid.
For example, a small PV system might use almost all its production itself and thus have high self-consumption, while it only covers a limited part of total annual consumption.
From solar panels to an integrated Home Energy System
The end of net-metering accelerates a development that has been technically visible for some time.
A home is increasingly becoming less of a collection of separate electrical appliances and more of one integrated energy system.
In such a system, the following can work together:
- solar panels for local production;
- a hybrid inverter for energy conversion and battery control;
- a home battery for time-shifting energy;
- a Smart Meter or P1 interface for real-time grid measurement;
- an electric vehicle as a large controllable load;
- a heat pump as a thermally and electrically controllable load;
- an EMS for decisions based on production, consumption, battery status, and energy tariffs.
The technical design question then becomes not just how much energy is produced, but especially when energy is produced, when it is needed, and which device can create the highest system value at which moment.
Energy management becomes at least as important as battery capacity
A battery without proper control is merely energy storage. Actual optimization arises through the control strategy.
For example, an EMS can take into account:
- actual PV production;
- actual home consumption;
- State of Charge of the battery;
- expected PV production;
- expected electricity consumption;
- dynamic electricity prices;
- import and export limits;
- available charging and discharging power.
Various storage architectures are available within the current Rebor range. The Rebor product export includes, among others, active solutions from SolisStorage, Dyness, Pylontech, BYD, and Anker SOLIX.
The choice between these systems should not be based solely on battery capacity. Compatibility between battery, BMS, hybrid inverter, firmware, and communication protocol remains leading.
Existing solar panels? The PV inverter does not always need to be replaced
Many Dutch homes already have a well-functioning grid-tied PV installation without a battery.
Adding storage does not automatically mean the entire existing PV system must be replaced.
Depending on the existing installation, battery storage can be added via a suitable AC-coupled architecture. Within certain Solis S6 configurations, for example, an existing PV inverter can be integrated into a new storage system via the configurable GEN/Smart Port.
This requires checking, among other things, the permitted power, energy measurement, export control, phase configuration, firmware, battery compatibility, and any backup function.
For the technical architecture, read our deep dive on expanding an existing PV installation with battery storage via the Solis Smart Port.
What role can a home battery play from 2027?
A home battery can serve multiple purposes. These goals must be distinguished from each other in advance, as they can lead to different sizing and control strategies.
| Goal | Battery function | Key design variables |
|---|---|---|
| Increase self-consumption of solar power | Store daytime PV surplus for later use | PV surplus, evening consumption, capacity, efficiency |
| Utilize dynamic tariffs | Charge and discharge based on price fluctuations | Tariff spread, cycles, efficiency, EMS |
| Peak shaving | Limit power peaks | kW power, response time, grid connection |
| Back-up | Power selected loads during grid outages | Continuous power, peak power, autonomy, system architecture |
| Combination strategy | Combine multiple goals | EMS logic, capacity, power reserve, priorities |
A system designed primarily for self-consumption may therefore have a different optimal battery capacity than a system that must also support back-up, dynamic trading, or peak shaving.
10 solar panels do not automatically mean a 10 kWh battery
The number of solar panels does not directly determine the required battery capacity.
Suppose a PV installation produces 18 kWh on a sunny day. If the home consumes 8 kWh of that during the production period, a theoretical surplus of 10 kWh remains.
But that still does not automatically mean that a 10 kWh battery is optimal.
The following must then be investigated:
- how often such a surplus actually occurs;
- how much evening and night-time consumption is available;
- what portion of the battery capacity is usable;
- whether the charging power is sufficient to absorb the surplus in time;
- whether the discharge power matches the household load;
- how much energy is lost due to conversion losses;
- whether a smaller battery can be utilized fully through cycles more frequently.
Best practice: size battery storage based on the profile of available energy and future demand, not exclusively on the number of solar panels or annual electricity consumption.
What does more self-consumption mean financially?
The financial value of additional self-consumption arises because a portion of grid purchases is avoided.
For every additional kWh of solar power meaningfully shifted to a later moment of consumption, one must therefore determine the difference between:
the avoided costs of electricity procurement and the economic value that the same kWh would have had with direct feed-in.
With storage, this difference must then be corrected for conversion losses and other system costs.
A simple theoretical example:
| Step | Example |
|---|---|
| PV surplus available | 5.0 kWh |
| Energy actually stored | Dependent on charging power and available capacity |
| Energy usable later | Storage minus conversion and system losses |
| Financial value | Avoided purchase minus missed feed-in value |
Without a current contract price, feed-in tariff, battery efficiency, and actual energy profile, no responsible universal euro amount can be linked to this.
Solar panels remain valuable, but the KPIs are changing
Both the national government and Milieu Centraal emphasize that solar panels will continue to provide value even after the net-metering scheme ends.
The way that value is created, however, is changing.
| Until the end of 2026 | From 2027 onwards |
|---|---|
| Generation and annual net-metering are highly decisive | Direct self-consumption is more important |
| Time of production is financially less critical | Time of production and consumption is more important |
| Feed-in can be offset within the scheme | Feed-in receives a separate economic value |
| Battery is primarily an additional system choice | Storage becomes more relevant for energy shifting and EMS |
Rebor best practice: design the complete energy system from 2027
The most future-proof approach is not to select solar panels, battery, and energy management independently of one another.
Assess the complete system in this order:
1. Consumption profile → 2. PV profile → 3. Direct self-consumption → 4. Available surplus → 5. Controllable loads → 6. Desired storage function → 7. Battery capacity → 8. Charge and discharge power → 9. Inverter compatibility → 10. BMS and communication → 11. Smart Meter / EMS → 12. Financial scenario analysis.
This prevents both under-dimensioning and costly over-dimensioning.
For installers and engineers, this means that battery advice does not stop at kWh. A complete design must also look at kW, phasing, grid connection, communication, compatibility, firmware, back-up requirements, and control strategy.
Conclusion: the end of net-metering is the start of smarter energy use
As of January 1, 2027, the net-metering scheme will disappear, but the value of solar energy will not.
The financial focus shifts from annual settling to direct self-consumption, smart power control, and targeted energy storage.
For many households, the first step is simple: use electrical appliances as much as possible when the solar panels are producing power.
After that, one can investigate how much additional self-consumption is technically feasible with a home battery.
A battery should not be chosen because net-metering is stopping. A battery should be chosen because the actual energy profile, available PV surpluses, future electricity usage, system compatibility, and the financial business case collectively demonstrate that storage adds value.
The core of the energy system from 2027: produce locally, use directly where possible, steer flexible consumption to favorable moments, and store only that portion of energy for which storage creates technical and economic value.
Frequently asked questions about the end of net-metering
When does the net-metering scheme stop?
The net-metering scheme stops on January 1, 2027. From that moment on, fed-back electricity can no longer be offset against electricity drawn from the grid at a different time.
Will I still receive money for solar power fed back from 2027?
Yes. A compensation for fed-back electricity will remain. According to the current information from the national government, this compensation must be at least 50% of the gross supply tariff until 2030. The final economic return is contract-dependent and can also be influenced by feed-in costs.
Will solar panels still be profitable from 2027?
Solar panels will continue to provide financial value because directly used solar power does not need to be purchased from an energy supplier, and fed-back electricity still generates a return. The actual payback period depends on factors such as purchase price, electricity price, production, self-consumption, feed-in tariff, and feed-in costs.
How much solar power does a household consume itself on average?
Milieu Centraal uses approximately 30% direct self-consumption as an average starting point without active control. By shifting consumption to solar hours, this percentage can increase.
Do I automatically need a home battery from 2027?
No. Start by analyzing and, where possible, shifting direct electricity consumption. A home battery becomes interesting when there is a structural PV surplus available that can be put to good use later, and the technical and financial business case is positive.
How large should my home battery be?
That cannot be responsibly derived solely from annual consumption or the number of solar panels. Daily PV surplus, evening and night consumption, usable capacity, charge and discharge power, battery efficiency, energy contract, and future electrical appliances must all be included in the assessment.
Can a home battery prevent all of my feed-in?
Not necessarily. On sunny days, PV production can be greater than both the direct consumption and the available battery capacity. In addition, charging power, State of Charge, and the system control strategy are decisive. A battery should therefore not be seen as a guarantee for zero feed-in.
Is a larger home battery always better financially?
No. Extra capacity only creates value when that capacity can be charged often enough and discharged usefully later. A battery that is too large may have a lower utilization rate and a less favorable investment ratio.
Can I add battery storage to existing solar panels?
In many situations, retrofitting is possible. The suitable architecture depends on the existing PV inverter, the desired battery system, phasing, energy metering, communication, compatibility, and any back-up function. AC-coupling may be a solution in certain systems without replacing the existing PV installation entirely.
Technical sources and methodology
This knowledge base page is constructed from current public information and technical system knowledge. For laws and regulations, the national government is the leading authority. For consumer calculations and assumptions regarding solar panels and self-consumption, current information from Milieu Centraal has been used.
For Rebor system choices, a distinction is made between product status, technical specifications, and compatibility. Active product status is checked against the current Rebor product export. Product-specific technical compatibility must always be confirmed with the official documentation and compatibility lists from the relevant manufacturers.
[1] National Government: Net-metering scheme ends in 2027
Primary source for the termination of the net-metering scheme as of January 1, 2027, the system after 2027, and the minimum feed-in compensation until 2030.
[2] Milieu Centraal: Net-metering scheme for solar panels
Source for current explanation of net-metering, average direct self-consumption, and the increasing importance of directly using one's own solar power.
[3] Milieu Centraal: Price and yield of solar panels
Source for current example calculations including 10 solar panels, approximately 30% self-consumption, annual savings from 2027, and the calculation assumption used for fed-back electricity.
[4] Milieu Centraal: Consuming more solar power yourself
Source for examples of higher self-consumption through shifting household appliances, smart use of a heat pump, and charging an electric car with solar power.
[5] Rebor B.V. : current product export and technical knowledge base
Used for the current status of storage categories and for internal references to battery advice, hybrid inverters, energy storage, and retrofit architectures. Concrete compatibility between battery, BMS, and inverter must always be checked against official manufacturer documentation.
Delve deeper into home batteries and energy management
Use the following Rebor knowledge paths to continue designing from your energy profile:
- Home battery calculator: determine the appropriate storage capacity
- SolisStorage home battery and energy storage
- Dyness home batteries and storage systems
- Pylontech energy storage
- BYD Battery-Box home batteries
- Anker SOLIX home battery and energy management
- Solis hybrid inverters and energy management
- Expanding existing solar panels with battery storage via Solis Smart Port